Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
 
 
 
 
 
Glass Tube Flowmeter
LZB/LZJ series glass rot...
Glass Tube Flowmeter
Glass Tube Flowmeter
LZB-()W/WB series micro ...
Glass Tube Flowmeter

 


CFZC Automatic Ration Loading Control System

 

 The automatic ration distribution system of distribution type ration loading control system is composed
of loading controlling instrument, flow meter, thermometer, level meter, ground switch, control valve,
explosion proof LED screen, and upper computer etc; the system is capable of either isolated operation
that is operated and monitored by operators locally or realizing computer operated loading control
through connection with the computers in the control chamber with communication cables; it collects
the loading information on the site to the control chamber for centralized monitoring, management,
displaying, and printing of various loading reports by computers.
Main Functions
1. Functions of automatic oil distribution and centralized management: it can realize automation of oil
distribution process, ensuring a highest loading accuracy that is over ± 0.2%; improving the
efficiency of production.
2. Function of safety alarm and protection: it can alarm for various system faults as well as protect for
static oil spilling and emergency system shutdown.
3. Monitoring function of loading process: it monitors the state of oil distribution of each crane
position on line.
4. Oil distribution upon bill change: it can be set for printing loading bills and save such bills; besides,
it has security code identification function.
5. Offline loading function: in case that the upper computable is inoperable, it can be easily shifted to
local loading mode.
6. Management function: it can arrange production by accepting production data and production
schedule from various higher level management networks, generating many types of reports.
7. Communication connection function: it provides with standard DDE and OPC interfaces that can
realize communication with such controls as DCS and ERP etc as well as the management system.
Main Features:
1. Adopting CFZ ration loading controlling instrument of domestic price and import performance;
2. Unique networking mode that can be shifted between Ethernet and RS 485;
3. The communication of upper computer and the loading controlling instrument adopts two standard
ways as TCP / IP and MODBUSRTU.
4. Software for upper computer can adopt general configuration software that is easy for maintenance.
5. Flexible configuration mode; it is even more easy and flexible for selection of types of local
instruments.
6. Both upper and lower computers are of complete Chinese environment.
7. Easy for extension and easy to integrate with modern network technologies.

Equipment Structure:
1. Industrial grade core intelligent controller.
2. Integrated liquid crystal display (LCD)
operation terminal of industrial grade.
3. Other industrial grade accessories.
Applicable Fields:
1. Ration truck loading and barreling of liquid
materials in such industries as petroleum,
chemical, pharmaceutical industries etc.
2. Rationed dosing of materials for production
processes and rationing control of other
processes.
Main functions:
1. Data acquiring and rationing control functions.
2. Parameter setup and sequencing control functions.
3. Oil spilling interlock, grounding interlock, emergency shutdown interlock, and power failure
protection functions.
4. Remote / local loading shifting function
5. Realizing monitoring and alarm functions
6. Communication networking function.
7. Equipment self check and security code protection functions.
Main Features:
1. Simple structure, extremely stable performance.
2. Module design that is easy for maintenance.
3. Providing with two standard communication interfaces for RS 485 and RJ 45.
4. Providing with standard MODBUSRTU and TCP / IP protocols for the convenience of networking,
configuration and communication with other PLC and DCS systems etc.
5. Providing with many types of data acquiring interfaces such as impulse input, AI, AO, DI, DO etc
which are of wide use range

Power supply AC 220 V, 2 A, 50 Hz

Liquid crystal display (LCD) STN LCD module of high lightness

Keyboard input 24 keys (built-in IC card is available for choice)

Equipment self check Automatically checking the working state of the equipment,

which can be remotely monitored

Flow signals 4 groups of impulse input from 0 to 10 kHz and two channels of

analog signal (4 ~ 20) mA can be connected

Valve position signal Valve position signal of up to 13 switch contacts can be

connected

Adjusting output 4 – 20 mA, electrical or pneumatic operated adjusting valve can

be controlled with PID loop control to realize constant current

or constant voltage control

Relay output AC 220 V, 5 A, which can control 10 valves or pumps

System accuracy Accumulated flow error (0.1% FS)

Mode of operation It is capable of 24-hour continuous operation without

interruption and can be locally or remotely operated

Operation temperature - 40℃ ~ 70℃

Storage temperature - 50℃ ~ 80℃

RH (relative humidity) 0 ~ 100%

Vibration 0.5 mm displacement, (10 ~ 55) Hz, in three direction of X, Y,

and Z in 2 hours

Ration range to set 0 ~ 99999999

Communication interface RS 485

Communication protocol Standard Modbus RTU (serial port); direct communication with

third party’s DCS hardware can be realized

Communication rate 100 Mbps (Ethernet), 600 ~ 115200 bps (serial port)

MTBF (mean time between

failures)

MTBF > 100,000 H (11 years)

Mark of explosion proof ExdIIBT6

Installation Wall mount type (cabinet type is available for choice)

Size 400 mm x 380 mm x 250 mm

Size of electrical interface G1 ” (4)

 

Power supply AC 220 V, 2 A, 50 Hz

Liquid crystal display (LCD) STN LCD module of high lightness

Keyboard input 24 keys (built-in IC card is available for choice)

Equipment self check Automatically checking the working state of the equipment,

which can be remotely monitored

Flow signals 4 groups of impulse input from 0 to 10 kHz and two channels of

analog signal (4 ~ 20) mA can be connected

Valve position signal Valve position signal of up to 13 switch contacts can be

connected

Adjusting output 4 – 20 mA, electrical or pneumatic operated adjusting valve can

be controlled with PID loop control to realize constant current

or constant voltage control



? 2012 Changzhou Chengfeng Flowmeter Co.,Ltd All Rights Reserved   Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
Design by Lingdong Internet  Switchboard:86-519-85503558,86-519-85503688  Fax:86-519-85505269,86-519-85503588-8008
Friendly Links:成豐儀表阿里巴巴店鋪    新浪    
主站蜘蛛池模板: 怀宁县| 益阳市| 柳州市| 湘乡市| 个旧市| 平顶山市| 闽侯县| 汉中市| 漳平市| 历史| 通许县| 临城县| 乌审旗| 乌海市| 永仁县| 子洲县| 北京市| 积石山| 龙海市| 定兴县| 洪江市| 黄石市| 贺兰县| 翼城县| 青神县| 南京市| 疏勒县| 新疆| 巴南区| 玛纳斯县| 宁津县| 桑日县| 山东| 托克逊县| 北流市| 宜兴市| 灌南县| 盐池县| 高青县| 武清区| 塔河县| 邯郸县| 湖南省| 广河县| 临泉县| 来宾市| 邻水| 贵定县| 康保县| 望都县| 嵊州市| 密山市| 西充县| 赤壁市| 泽州县| 潜江市| 连南| 多伦县| 大关县| 土默特右旗| 太谷县| 天门市| 皋兰县| 日土县| 上虞市| 阿拉善右旗| 宣威市| 阿勒泰市| 红安县| 象山县| 和顺县| 大港区| 修文县| 克什克腾旗| 广汉市| 鹤峰县| 沧源| 江西省| 安乡县| 德昌县| 中超| 额敏县|